We heard from time to time some of our customers come to us ask for help for gas grill gets low flame.
Usually there is about 7 common scene to cause this situation
The very frenquent one is regulator issues. This assembly might need to be reset on the hose before it screws into the propane tank.
1. Turn off the gas at the propane tank.
2. Disconnect the hose from the propane tank.
3. Open the lid of your BBQ Grill.
4. Turn all the burner valves to high.
5. Wait for 2 minutes.
6. Turn off all the burner valves.
7. Connect the gas line back up to the propane tank.
8. Turn the gas on slowly on the propane tank.
9. Light the grill using your normal lighting procedures.
If the regulator was stuck, it should have been reset using these steps.
If you always turn off your burner valves first before turning off the gas at the tank, you will keep the regulator from sticking again.
If you still have low flame or yellow flame, give it a second try, although you might have a faulty regulator that is causing the low flame or yellow flame. That will need to be replaced if it is bad.
Leak in the fuel supply
Another very common issue that impacts weak or yellow flame output is a leak between the tank and the grill.
To troubleshoot, apply soapy water to the propane tank valve, connector, hose, all the way up to where the hose connects to the burner assembly on your grill. Look for bubbles to indicate small leaks of the gas source. If you have any leaks, for safety reasons, get them repaired or replaced immediately.
Leak in the gas supply caused OPD safety valve shutting dwon
This can be caused by the OPD safety valve in the Propane tank being tripped. A reason why the safety valve might have tripped could be that it detected a leak somewhere between the propane tank and the burner (including a burner not being turned off all the way).
The leak would cause a small amount of propane to leak from the tank which would trip the safety valve much like a circuit breaker in a breaker box. After the safety valve is tripped, only a small amount of propane is allowed out of the tank, causing a small flame.
Steps to reset the OPD safety valve:
1. Use soapy water (not a match) to check the hose and the connections within the grill for leaks
2. Turn the propane tank valve off
3. Open and shut a grill burner valve on the Barbeque grill
4. Make sure all the grill burners and the propane tank valve is off.
5. Disconnect the hose from the propane tank
6. Reconnect the hose back to the propane tank
Those steps should reset the OPD Safety valve on the propane tank.
Now it is time to test the tank. Open the valve on the propane tank 2 turns slowly (not all the way on).
Light the grill as normal.
The blockage in venturis
Unhook the hose from the tank and check the grill burner assembly and venturis for obstructions. I have had spiders crawl into the pipes and build a spider web which restricted the amount of gas that could flow from the tank to the grill burners. Follow your manufacturers instructions for doing this check.
The Venturi shutters also might need to be adjusted. Find the venturi tube adjustment screw. This screw releases the shutters. Light the grill and set to low heat. Loosen the venturi screw and open the shutters until the flame is mostly blue. Turn off gas and tighten the adjustment screw. Let the grill cool.
Propane tank might be not work
Try hooking up a different tank to the grill to see if the problem goes away. Some customer wasted a whole 5 gallons of propane with a tank that went bad. A new tank fixed his problem.
The blockage in the regulator hose
Some customer submit the following via phone text. He was having problems with his nexgrill 6 burner grill. Everything worked fine when lighting the burners until he lit the 6th burner. When the sixth burner was turned on, the other five either go out or the flame turns really low and then goes out.
He talked to nexgrill customer service and they reported that sometimes the regulator hose gets a gas blockage.
They advised him to correct it by turning off the tank, disconnecting the hose, open the grill and side burner and any other systems, open the controls to full open and leave for 45 sec to 1 minute.
Re-connect the hose, turn on the tank and attempt a re-light on the grill. If it still doesn’t work, it could be the regulator hose. His fired right up with no problems.
Propane tank handling:
Always open your propane tank valve slowly to keep the pressure in the tank from overwhelming your OPD valve or the regulator. Wait a few moments after turning the gas on before lighting the grill. This will allow time for the pressure to even out before lighting the grill.
Please be very careful before you start to fix it! Rember to turn everything off, including your gas flow at the tank.
Hope this article could help you a little, and if there's any need of replacement your gas grill burner or hose, tank, regulator or valve, welcome to buy quality and cheaper one at our site.